1.
Anal Chem ; 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38739527

RESUMEN

Mass spectrometry has been increasingly explored in intraoperative studies as a potential technology to help guide surgical decision making. Yet, intraoperative experiments using high-performance mass spectrometry instrumentation present a unique set of operational challenges. For example, standard operating rooms are often not equipped with the electrical requirements to power a commercial mass spectrometer and are not designed to accommodate their permanent installation. These obstacles can impact progress and patient enrollment in intraoperative clinical studies because implementation of MS instrumentation becomes limited to specific operating rooms that have the required electrical connections and space. To expand our intraoperative clinical studies using the MasSpec Pen technology, we explored the feasibility of transporting and acquiring data on Orbitrap mass spectrometers operating on battery power in hospital buildings. We evaluated the effect of instrument movement including acceleration and rotational speeds on signal stability and mass accuracy by acquiring data using direct infusion electrospray ionization. Data were acquired while rolling the systems in/out of operating rooms and while descending/ascending a freight elevator. Despite these movements and operating the instrument on battery power, the relative standard deviation of the total ion current was <5% and the magnitude of the mass error relative to the internal calibrant never exceeded 5.06 ppm. We further evaluated the feasibility of performing intraoperative MasSpec Pen analysis while operating the Orbitrap mass spectrometer on battery power during an ovarian cancer surgery. We observed that the rich and tissue-specific molecular profile commonly detected from ovarian tissues was conserved when running on battery power. Together, these results demonstrate that Orbitrap mass spectrometers can be operated and acquire data on battery power while in motion and in rotation without losses in signal stability or mass accuracy. Furthermore, Orbitrap mass spectrometers can be used in conjunction to the MasSpec Pen while on battery power for intraoperative tissue analysis.

2.
JAMA Netw Open ; 7(3): e242684, 2024 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-38517441

RESUMEN

Importance: Surgery with complete tumor resection remains the main treatment option for patients with breast cancer. Yet, current technologies are limited in providing accurate assessment of breast tissue in vivo, warranting development of new technologies for surgical guidance. Objective: To evaluate the performance of the MasSpec Pen for accurate intraoperative assessment of breast tissues and surgical margins based on metabolic and lipid information. Design, Setting, and Participants: In this diagnostic study conducted between February 23, 2017, and August 19, 2021, the mass spectrometry-based device was used to analyze healthy breast and invasive ductal carcinoma (IDC) banked tissue samples from adult patients undergoing breast surgery for ductal carcinomas or nonmalignant conditions. Fresh-frozen tissue samples and touch imprints were analyzed in a laboratory. Intraoperative in vivo and ex vivo breast tissue analyses were performed by surgical staff in operating rooms (ORs) within 2 different hospitals at the Texas Medical Center. Molecular data were used to build statistical classifiers. Main Outcomes and Measures: Prediction results of tissue analyses from classification models were compared with gross assessment, frozen section analysis, and/or final postoperative pathology to assess accuracy. Results: All data acquired from the 143 banked tissue samples, including 79 healthy breast and 64 IDC tissues, were included in the statistical analysis. Data presented rich molecular profiles of healthy and IDC banked tissue samples, with significant changes in relative abundances observed for several metabolic species. Statistical classifiers yielded accuracies of 95.6%, 95.5%, and 90.6% for training, validation, and independent test sets, respectively. A total of 25 participants enrolled in the clinical, intraoperative study; all were female, and the median age was 58 years (IQR, 44-66 years). Intraoperative testing of the technology was successfully performed by surgical staff during 25 breast operations. Of 273 intraoperative analyses performed during 25 surgical cases, 147 analyses from 22 cases were subjected to statistical classification. Testing of the classifiers on 147 intraoperative mass spectra yielded 95.9% agreement with postoperative pathology results. Conclusions and Relevance: The findings of this diagnostic study suggest that the mass spectrometry-based system could be clinically valuable to surgeons and patients by enabling fast molecular-based intraoperative assessment of in vivo and ex vivo breast tissue samples and surgical margins.


Asunto(s)
Neoplasias de la Mama , Adulto , Femenino , Humanos , Persona de Mediana Edad , Masculino , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/cirugía , Neoplasias de la Mama/patología , Márgenes de Escisión , Mama/cirugía , Mama/patología , Mastectomía , Espectrometría de Masas
3.
JAMA Surg ; 158(10): 1050-1059, 2023 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-37531134

RESUMEN

Importance: Intraoperative identification of tissues through gross inspection during thyroid and parathyroid surgery is challenging yet essential for preserving healthy tissue and improving outcomes for patients. Objective: To evaluate the performance and clinical applicability of the MasSpec Pen (MSPen) technology for discriminating thyroid, parathyroid, and lymph node tissues intraoperatively. Design, Setting, and Participants: In this diagnostic/prognostic study, the MSPen was used to analyze 184 fresh-frozen thyroid, parathyroid, and lymph node tissues in the laboratory and translated to the operating room to enable in vivo and ex vivo tissue analysis by endocrine surgeons in 102 patients undergoing thyroidectomy and parathyroidectomy procedures. This diagnostic study was conducted between August 2017 and March 2020. Fresh-frozen tissues were analyzed in a laboratory. Clinical analyses occurred in an operating room at an academic medical center. Of the analyses performed on 184 fresh-frozen tissues, 131 were included based on sufficient signal and postanalysis pathologic diagnosis. From clinical tests, 102 patients undergoing surgery were included. A total of 1015 intraoperative analyses were performed, with 269 analyses subject to statistical classification. Statistical classifiers for discriminating thyroid, parathyroid, and lymph node tissues were generated using training sets comprising both laboratory and intraoperative data and evaluated on an independent test set of intraoperative data. Data were analyzed from July to December 2022. Main Outcomes and Measures: Accuracy for each tissue type was measured for classification models discriminating thyroid, parathyroid, and lymph node tissues using MSPen data compared to gross analysis and final pathology results. Results: Of the 102 patients in the intraoperative study, 80 were female (78%) and the median (IQR) age was 52 (42-66) years. For discriminating thyroid and parathyroid tissues, an overall accuracy, defined as agreement with pathology, of 92.4% (95% CI, 87.7-95.4) was achieved using MSPen data, with 82.6% (95% CI, 76.5-87.4) accuracy achieved for the independent test set. For distinguishing thyroid from lymph node and parathyroid from lymph node, overall training set accuracies of 97.5% (95% CI, 92.8-99.1) and 96.1% (95% CI, 91.2-98.3), respectively, were achieved. Conclusions and Relevance: In this study, the MSPen showed high performance for discriminating thyroid, parathyroid, and lymph node tissues intraoperatively, suggesting this technology may be useful for providing near real-time feedback on tissue type to aid in surgical decision-making.


Asunto(s)
Glándulas Paratiroides , Glándula Tiroides , Humanos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Glándulas Paratiroides/cirugía , Glándula Tiroides/cirugía , Paratiroidectomía , Tiroidectomía/métodos , Pronóstico
4.
Front Physiol ; 13: 839471, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35295579

RESUMEN

Synthetic oligonucleotide technologies are DNA or RNA based molecular compounds that are utilized to disrupt gene transcription or translation in target tissues or cells. Optimally, oligonucleotides are 10-30 base pairs in length, and mediate target gene suppression through directed sequence homology with messenger RNA (mRNA), leading to mRNA degradation. Examples of specific oligonucleotide technologies include antisense oligonucleotides (ASO), short hairpin RNAs (shRNA), and small interfering RNAs (siRNA). In vitro and in vivo studies that model obesity related disorders have demonstrated that oligonucleotide technologies can be implemented to improve the metabolism of cells and tissues, exemplified by improvements in fat utilization and hepatic insulin signaling, respectively. Oligonucleotide therapy has also been associated with reductions in lipid accumulation in both the liver and adipose tissue in models of diet-induced obesity. Recent advances in oligonucleotide technologies include the addition of chemical modifications such as N-acetylgalactosamine (GalNAc) conjugates that have been successful at achieving affinity for the liver, in turn improving specificity, and thus reducing off target effects. However, some challenges are still yet to be overcome relating to hepatic injury and off-target effects that have been reported with some compounds, including ASOs. In summary, oligonucleotide-based therapies are an effective tool to elucidate mechanistic insights into metabolic pathways and provide an attractive avenue for translational research into the clinic.

5.
Anal Chem ; 93(37): 12582-12593, 2021 09 21.
Artículo en Inglés | MEDLINE | ID: mdl-34432430

RESUMEN

The outbreak of COVID-19 has created an unprecedent global crisis. While the polymerase chain reaction (PCR) is the gold standard method for detecting active SARS-CoV-2 infection, alternative high-throughput diagnostic tests are of a significant value to meet universal testing demands. Here, we describe a new design of the MasSpec Pen technology integrated to electrospray ionization (ESI) for direct analysis of clinical swabs and investigate its use for COVID-19 screening. The redesigned MasSpec Pen system incorporates a disposable sampling device refined for uniform and efficient analysis of swab tips via liquid extraction directly coupled to an ESI source. Using this system, we analyzed nasopharyngeal swabs from 244 individuals including symptomatic COVID-19 positive, symptomatic negative, and asymptomatic negative individuals, enabling rapid detection of rich lipid profiles. Two statistical classifiers were generated based on the lipid information acquired. Classifier 1 was built to distinguish symptomatic PCR-positive from asymptomatic PCR-negative individuals, yielding a cross-validation accuracy of 83.5%, sensitivity of 76.6%, and specificity of 86.6%, and validation set accuracy of 89.6%, sensitivity of 100%, and specificity of 85.3%. Classifier 2 was built to distinguish symptomatic PCR-positive patients from negative individuals including symptomatic PCR-negative patients with moderate to severe symptoms and asymptomatic individuals, yielding a cross-validation accuracy of 78.4%, specificity of 77.21%, and sensitivity of 81.8%. Collectively, this study suggests that the lipid profiles detected directly from nasopharyngeal swabs using MasSpec Pen-ESI mass spectrometry (MS) allow fast (under a minute) screening of the COVID-19 disease using minimal operating steps and no specialized reagents, thus representing a promising alternative high-throughput method for screening of COVID-19.


Asunto(s)
COVID-19 , Pruebas Diagnósticas de Rutina , Humanos , Nasofaringe , SARS-CoV-2 , Sensibilidad y Especificidad , Manejo de Especímenes
6.
Clin Chem ; 67(9): 1271-1280, 2021 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-34263289

RESUMEN

BACKGROUND: Intraoperative tissue analysis and identification are critical to guide surgical procedures and improve patient outcomes. Here, we describe the clinical translation and evaluation of the MasSpec Pen technology for molecular analysis of in vivo and freshly excised tissues in the operating room (OR). METHODS: An Orbitrap mass spectrometer equipped with a MasSpec Pen interface was installed in an OR. A "dual-path" MasSpec Pen interface was designed and programmed for the clinical studies with 2 parallel systems that facilitated the operation of the MasSpec Pen. The MasSpec Pen devices were autoclaved before each surgical procedure and were used by surgeons and surgical staff during 100 surgeries over a 12-month period. RESULTS: Detection of mass spectral profiles from 715 in vivo and ex vivo analyses performed on thyroid, parathyroid, lymph node, breast, pancreatic, and bile duct tissues during parathyroidectomies, thyroidectomies, breast, and pancreatic neoplasia surgeries was achieved. The MasSpec Pen enabled gentle extraction and sensitive detection of various molecular species including small metabolites and lipids using a droplet of sterile water without causing apparent tissue damage. Notably, effective molecular analysis was achieved while no limitations to sequential histologic tissue analysis were identified and no device-related complications were reported for any of the patients. CONCLUSIONS: This study shows that the MasSpec Pen system can be successfully incorporated into the OR, allowing direct detection of rich molecular profiles from tissues with a seconds-long turnaround time that could be used to inform surgical and clinical decisions without disrupting tissue analysis workflows.


Asunto(s)
Neoplasias Pancreáticas , Humanos , Espectrometría de Masas , Paratiroidectomía , Glándula Tiroides
7.
Proc Natl Acad Sci U S A ; 118(28)2021 07 13.
Artículo en Inglés | MEDLINE | ID: mdl-34260388

RESUMEN

Intraoperative delineation of tumor margins is critical for effective pancreatic cancer surgery. Yet, intraoperative frozen section analysis of tumor margins is a time-consuming and often challenging procedure that can yield confounding results due to histologic heterogeneity and tissue-processing artifacts. We have previously described the development of the MasSpec Pen technology as a handheld mass spectrometry-based device for nondestructive tissue analysis. Here, we evaluated the usefulness of the MasSpec Pen for intraoperative diagnosis of pancreatic ductal adenocarcinoma based on alterations in the metabolite and lipid profiles in in vivo and ex vivo tissues. We used the MasSpec Pen to analyze 157 banked human tissues, including pancreatic ductal adenocarcinoma, pancreatic, and bile duct tissues. Classification models generated from the molecular data yielded an overall agreement with pathology of 91.5%, sensitivity of 95.5%, and specificity of 89.7% for discriminating normal pancreas from cancer. We built a second classifier to distinguish bile duct from pancreatic cancer, achieving an overall accuracy of 95%, sensitivity of 92%, and specificity of 100%. We then translated the MasSpec Pen to the operative room and predicted on in vivo and ex vivo data acquired during 18 pancreatic surgeries, achieving 93.8% overall agreement with final postoperative pathology reports. Notably, when integrating banked tissue data with intraoperative data, an improved agreement of 100% was achieved. The result obtained demonstrate that the MasSpec Pen provides high predictive performance for tissue diagnosis and compatibility for intraoperative use, suggesting that the technology may be useful to guide surgical decision-making during pancreatic cancer surgeries.


Asunto(s)
Tecnología Biomédica , Márgenes de Escisión , Espectrometría de Masas , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/cirugía , Anciano , Carcinoma Ductal Pancreático/diagnóstico , Carcinoma Ductal Pancreático/patología , Carcinoma Ductal Pancreático/cirugía , Conducto Colédoco/patología , Conducto Colédoco/cirugía , Femenino , Humanos , Cuidados Intraoperatorios , Masculino , Persona de Mediana Edad , Páncreas/patología , Páncreas/cirugía , Neoplasias Pancreáticas/patología , Estadística como Asunto
8.
Metabolites ; 11(6)2021 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-34070445

RESUMEN

Statins are the first-line lipid-lowering therapy for reducing cardiovascular disease (CVD) risk. A plasma lipid ratio of two phospholipids, PI(36:2) and PC(18:0_20:4), was previously identified to explain 58% of the relative CVD risk reduction associated with pravastatin, independent of a change in low-density lipoprotein-cholesterol. This ratio may be a potential biomarker for the treatment effect of statins; however, the underlying mechanisms linking this ratio to CVD risk remain unclear. In this study, we investigated the effect of altered cholesterol conditions on the lipidome of cultured human liver cells (Hep3B). Hep3B cells were treated with simvastatin (5 µM), cyclodextrin (20 mg/mL) or cholesterol-loaded cyclodextrin (20 mg/mL) for 48 hours and their lipidomes were examined. Induction of a low-cholesterol environment via simvastatin or cyclodextrin was associated with elevated levels of lipids containing arachidonic acid and decreases in phosphatidylinositol species and the PI(36:2)/PC(18:0_20:4) ratio. Conversely, increasing cholesterol levels via cholesterol-loaded cyclodextrin resulted in reciprocal regulation of these lipid parameters. Expression of genes involved in cholesterol and fatty acid synthesis supported the lipidomics data. These findings demonstrate that the PI(36:2)/PC(18:0_20:4) ratio responds to changes in intracellular cholesterol abundance per se, likely through a flux of the n-6 fatty acid pathway and altered phosphatidylinositol synthesis. These findings support this ratio as a potential marker for CVD risk reduction and may be useful in monitoring treatment response.

9.
Anal Chem ; 92(17): 11535-11542, 2020 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-32786489

RESUMEN

Minimally invasive robotic-assisted surgeries have been increasingly used as a first-line of treatment for patients undergoing oncologic surgeries. In-situ tissue identification is critical to guide tissue resection and assist decision-making. Traditional intraoperative histopathologic analysis of frozen tissue sections can be time-consuming and present logistical challenges which interrupt surgical workflows. We report the development and implementation of a laparoscopic, drop-in version of the MasSpec Pen device integrated into the da Vinci Xi Surgical system for in vivo tissue analysis in a robotic-assisted porcine surgery. We evaluated the performance of the drop-in MasSpec Pen during surgery by introducing the device into the animal upper gastrointestinal system and performing in vivo analyses of the stomach and liver, including charred and bloody tissues after electrocauterization. The molecular profiles obtained included ions tentatively identified as metabolites and lipids typically observed with MasSpec Pen analysis, without causing observable tissue damage. Statistical classifiers built to distinguish porcine liver and stomach tissues using the in vivo data yielded an overall tissue identification accuracy of 98% (n = 53 analyses). The results provide evidence that the drop-in MasSpec Pen developed can be used to acquire mass spectra in vivo during a robotic-assisted surgery and might be used as an in vivo tissue assessment tool to help guide surgical resections and streamline surgical workflows.


Asunto(s)
Procedimientos Quirúrgicos del Sistema Digestivo/instrumentación , Diseño de Equipo/instrumentación , Ácidos Grasos/análisis , Ácidos Grasos/metabolismo , Procedimientos Quirúrgicos Robotizados/instrumentación , Cirugía Asistida por Video/instrumentación , Animales , Femenino , Humanos , Técnicas In Vitro , Laparoscopía , Metabolismo de los Lípidos , Espectrometría de Masas , Prótesis e Implantes , Porcinos
10.
J Am Chem Soc ; 142(14): 6750-6760, 2020 04 08.
Artículo en Inglés | MEDLINE | ID: mdl-32203657

RESUMEN

Post-translational modifications create a diverse mixture of proteoforms, leading to substantial challenges in linking proteomic information to disease. Top-down sequencing of intact proteins and multiprotein complexes offers significant advantages in proteoform analysis, but achieving complete fragmentation for such precursor ions remains challenging. Intact proteins that undergo slow-heating generally fragment via charge directed (i.e., mobile proton) or charge remote fragmentation pathways. Our efforts seek to alter this paradigm by labeling proteins with trimethyl pyrylium (TMP), which forms a stable, positively charged label at lysine residues. Fixing positive charges to the protein sequence reduces the availability of mobile protons, driving fragmentation to charge remote channels. Furthermore, we demonstrate that capping acidic side chains with carbodiimide chemistry obstructs this pathway, restoring charge-directed fragmentation and resulting in more even coverage of the protein sequence. With large amounts of fixed charge and few mobile protons, we demonstrate that it is also possible to direct fragmentation almost exclusively to lysine residues containing the charged label. Finally, our data indicate that when electrosprayed under native conditions, protein ions possess an immense capacity to accommodate excess positive charge. Molecular dynamics simulations of such ions bearing intrinsically charged labels reveal evidence of numerous charge solvation processes, including the preferential formation of helices that solvate charged labels through interactions with their macro-dipoles. Thus, these studies reveal the extent to which intact gas-phase protein ions are capable of solvating charge, and provide the most complete indication to date of the extensive physical forces opposing the goal of comprehensive top-down protein sequencing.


Asunto(s)
Iones/química , Simulación de Dinámica Molecular/normas , Proteínas/química , Proteómica/métodos , Secuencia de Aminoácidos
11.
Nature ; 567(7747): 187-193, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30814737

RESUMEN

Dysregulation of lipid homeostasis is a precipitating event in the pathogenesis and progression of hepatosteatosis and metabolic syndrome. These conditions are highly prevalent in developed societies and currently have limited options for diagnostic and therapeutic intervention. Here, using a proteomic and lipidomic-wide systems genetic approach, we interrogated lipid regulatory networks in 107 genetically distinct mouse strains to reveal key insights into the control and network structure of mammalian lipid metabolism. These include the identification of plasma lipid signatures that predict pathological lipid abundance in the liver of mice and humans, defining subcellular localization and functionality of lipid-related proteins, and revealing functional protein and genetic variants that are predicted to modulate lipid abundance. Trans-omic analyses using these datasets facilitated the identification and validation of PSMD9 as a previously unknown lipid regulatory protein. Collectively, our study serves as a rich resource for probing mammalian lipid metabolism and provides opportunities for the discovery of therapeutic agents and biomarkers in the setting of hepatic lipotoxicity.


Asunto(s)
Metabolismo de los Lípidos/genética , Lípidos/análisis , Lípidos/genética , Proteómica , Animales , Células HEK293 , Humanos , Metabolismo de los Lípidos/fisiología , Lípidos/sangre , Lípidos/clasificación , Hígado/química , Hígado/metabolismo , Hígado/patología , Masculino , Ratones , Ratones Endogámicos C57BL , Ratones Endogámicos DBA , Obesidad/genética , Obesidad/metabolismo , Complejo de la Endopetidasa Proteasomal/química , Complejo de la Endopetidasa Proteasomal/genética , Complejo de la Endopetidasa Proteasomal/metabolismo
12.
J Neurosurg ; 132(1): 180-187, 2019 01 04.
Artículo en Inglés | MEDLINE | ID: mdl-30611146

RESUMEN

OBJECTIVE: The authors describe a rapid intraoperative ambient ionization mass spectrometry (MS) method for determining isocitrate dehydrogenase (IDH) mutation status from glioma tissue biopsies. This method offers new glioma management options and may impact extent of resection goals. Assessment of the IDH mutation is key for accurate glioma diagnosis, particularly for differentiating diffuse glioma from other neoplastic and reactive inflammatory conditions, a challenge for the standard intraoperative diagnostic consultation that relies solely on morphology. METHODS: Banked glioma specimens (n = 37) were analyzed by desorption electrospray ionization-MS (DESI-MS) to develop a diagnostic method to detect the known altered oncometabolite in IDH-mutant gliomas, 2-hydroxyglutarate (2HG). The method was used intraoperatively to analyze tissue smears obtained from glioma patients undergoing resection and to rapidly diagnose IDH mutation status (< 5 minutes). Fifty-one tumor core biopsies from 25 patients (14 wild type [WT] and 11 mutant) were examined and data were analyzed using analysis of variance and receiver operating characteristic curve analysis. RESULTS: The optimized DESI-MS method discriminated between IDH-WT and IDH-mutant gliomas, with an average sensitivity and specificity of 100%. The average normalized DESI-MS 2HG signal was an order of magnitude higher in IDH-mutant glioma than in IDH-WT glioma. The DESI 2HG signal intensities correlated with independently measured 2HG concentrations (R2 = 0.98). In 1 case, an IDH1 R132H-mutant glioma was misdiagnosed as a demyelinating condition by frozen section histology during the intraoperative consultation, and no resection was performed pending the final pathology report. A second craniotomy and tumor resection was performed after the final pathology provided a diagnosis most consistent with an IDH-mutant glioblastoma. During the second craniotomy, high levels of 2HG in the tumor core biopsies were detected. CONCLUSIONS: This study demonstrates the capability to differentiate rapidly between IDH-mutant gliomas and IDH-WT conditions by DESI-MS during tumor resection. DESI-MS analysis of tissue smears is simple and can be easily integrated into the standard intraoperative pathology consultation. This approach may aid in solving differential diagnosis problems associated with low-grade gliomas and could influence intraoperative decisions regarding extent of resection, ultimately improving patient outcome. Research is ongoing to expand the patient cohort, systematically validate the DESI-MS method, and investigate the relationships between 2HG and tumor heterogeneity.


Asunto(s)
Neoplasias Encefálicas/enzimología , Glioma/enzimología , Cuidados Intraoperatorios/métodos , Isocitrato Deshidrogenasa/genética , Proteínas de Neoplasias/genética , Espectrometría de Masa por Ionización de Electrospray , Adulto , Astrocitoma/enzimología , Astrocitoma/genética , Astrocitoma/patología , Astrocitoma/cirugía , Biopsia , Neoplasias Encefálicas/genética , Neoplasias Encefálicas/patología , Neoplasias Encefálicas/cirugía , Craneotomía , Femenino , Glioblastoma/enzimología , Glioblastoma/genética , Glioblastoma/patología , Glioblastoma/cirugía , Glioma/genética , Glioma/patología , Glioma/cirugía , Humanos , Isocitrato Deshidrogenasa/análisis , Masculino , Persona de Mediana Edad , Reoperación , Adulto Joven